Laser Safety Curtain for Laser Welding

LMT-Weld-Curtain
search
  • LMT-Weld-Curtain
  • LMT-Weld-Curtain

Reference number: LMT-Weld-Curtain

Laser safety curtain for delimiting laser welding areas.

alt

Need more info?
Contact our expert.

Laser Safety Team
Phone: +49 8153 405-11

Description

Laser Safety Curtain Weld-Curtain


The laser safety curtain Weld-Curtain is suitable for delimiting laser welding areas to block direct scattered light from the welding laser. Standard widths from 0.7 m to 8.7 m with heights of up to 4.00 m can be manufactured to exact dimensions. Several curtains can be firmly connected with Velcro so that, for example, a rectangular work area can be delimited. Suitable rail systems for mounting the curtain directly to the ceiling or suspended from a high ceiling with vertical rods are optionally available..

    • CE certified according to the standard EN 60825-4 (Safety of laser equipment - Part 4: Laser protection walls)
    • Flame retardant (M2 protection level according to NFP 92-503)
    • Material: Both sides black
    • Curtain weight: 1.3 kg/m²
    • Surface easy to clean
    • Eyelets (diameter 10 mm, standard spacing 120 mm) and metal hooks on the top edge
    • Matching curtain track available
    • Attachment of additional screens possible (to cover the gap between the rail and the upper edge of the curtain)
    • Attachment of Velcro possible
    • Connection with interlock system possible 

Protection values according to EN 60825-4

Please note that the curtain material only protects against stray light from the laser when using a hand-held laser welding device as intended. It is necessary for the laser protection officer in your company to confirm as part of a risk assessment that the maximum permissible radiation levels of the curtain are not being reached or exceeded. Scattered radiation, which can escape upwards, downwards or sideways, must be evaluated by the laser safety officer with regard to maximum permissible radiation levels depending on the on-site situation. Additional laser protection measures may be required.

Irradiated area

 PEL* (T3) 10 s

PEL (T2) 100 s

4 mm2

3.9 MW/sqm

2.2 MW/sqm

2000 mm2

0.62 MW/sqm

0.35 MW/sqm

* PEL = Permissible Exposure Limits